 Part NumberOCL +/- 7.5% uHTurns Ratio Chip:Line +/- 2%Leakage uH MaxDCR Chip Max OhmsDCR Line Max OhmsDielectric Strength Vrms MinConfiguration / SchematicApplicationQuantity
316404401:1:1:115.00.501.001500**23x11 THDCP
340251021:1:2:25.00.641.161500**RM8 THDCO
34026844 min1:2:4.5 CT1.00.300.40600EP10 THDCO
336844401:1:1:115.00.601.601500**EP13 THD/ACP
340241021:1:2:25.00.250.401500*EP13 THD/ACO
321887680 min1:2:1.64 CT3.02.551.95600EP10 THDCP
369524401:1:1:115.00.801.001500**EP13 THD/ACP
343184401:1:1:115.00.601.601500**EP13 SMDCP
321862341:15.00.67500RM4 THDAF Transformer 
327612341:17.00.67500EP13 THD/BAF Transformer 
321872821:15.00.95500RM4 THDAF Transformer 
327622821:17.00.95500EP13 THD/BAF Transformer 
321895001:110.04.105009X5 THDLF Transformer 
327635001:17.03.80500EP7 THD/ALF Transformer 
3368191*1:15.00.70500EP7 THD/AAF Transformer 
3368396N/AN/A0.42500EP7 THD/BInductor 
345183.3 min1:10.61.01.0650Toroid SMDCO/CPE
 

Parts availability subject to Schott manufacturing schedules and leadtimes. Not all parts available from stock. Please contact us for more details and availability. The Adobe Acrobat Reader is required to view these linked documents.
 
Electrical Specifications Test Criteria

  1. These transformers are designed for operating within a temperature range of -40°C to +85°C. All electrical characteristics are reported for operating at 25°C. 
  2. Inductance (OCL) is measured at 10KHz, 0.1Vrms, IWC is measured at 10KHz, 0.01 Vrms. 
 

 


All data is believed to be accurate at time of printing. Schott Corporation reserves the right to make changes without notification. “Schott” is a trade name of Schott Corporation. All other trademarks and trade names are the property of their respective holder. © 2001 Schott Corporation.

Last Modified: 12/14/2001 2:32:40 PM

 

 

 

Schott World Headquaters
For over a half a century, Schott has specialized in the manufacture and design of a wide range of high quality transformers, inductors, and magnetic components made to customer specifications.

Schott Magnetics EU RoHS Compliance

 

 

Sales and customer service:
(507)223-5572 ext 104,
(507)223-5055 fax

Email:
sales@schottmagnetics.com
Engineering: (507)223-5572 ext 105
eng@schottmagnetics.com
Corporate office: (619)661-1261